FD30 vs FD60 Fire Doors
FD30 and FD60 fire doors are rated to resist fire for 30 and 60 minutes respectively. The number is not a matter of preference: it comes from the building's fire strategy, based on how long people need to escape and how the building is compartmentalised. Getting the rating wrong in either direction, too low or unnecessarily high, causes real problems.
By Daniel, Director · 4 August 2026 · 5 min read
What FD30 and FD60 mean

The number refers to the time, in minutes, that a complete doorset (the leaf, frame, seals and ironmongery together) is tested to resist the passage of fire under standard test conditions. FD30 holds for 30 minutes, FD60 for 60. Some doors also carry an "s" suffix, such as FD30s, meaning the doorset additionally resists cold smoke, which matters most on escape routes where smoke inhalation is often the greater danger.
How the rating is decided for a building
The rating comes from the building's fire strategy, not from the door manufacturer's catalogue. A fire risk assessment or a fire engineer's design will specify which rating each door in the building needs, based on factors including how the building is divided into fire compartments, how far people need to travel to escape, and what other fire protection measures, such as sprinklers, are in place.
FD30 is the most common rating for internal doors on escape routes in typical commercial and residential buildings. FD60 is more often specified for doors protecting higher-risk areas, such as plant rooms, or in buildings with a more demanding fire strategy, such as taller residential blocks.
Which internal doors need a rating
Not every internal door in a building needs to be a fire door. Doors that form part of a designated escape route, that separate different fire compartments, or that protect a stairwell almost always do. A cupboard door or a door between two rooms in the same open-plan office, where no compartment line runs through it, typically does not. This is exactly the kind of detail a survey settles, rather than relying on a general assumption either way.